Roofs that have failed, on buildings that cannot stop. Most of our repair work is this: the old membrane stripped and a new system laid, in sections, between the rain. This page sets out the layers, the order of work and the test we carry out before we leave.

2Coats of MONOLITHIC MEMBRANE 6130K, applied hot, with FLEX FLASH F fabric between them.
300 mmThe least the system turns up every wall and upstand.
24Hours the roof stays flooded for the pond test.

The build-up.

Three layers on the stripped slab.

From the slab up

  1. MONOLITHIC MEMBRANE 6130KHot-applied rubberised asphalt, seamless, on the stripped and cleaned slab. Two coats, with FLEX FLASH F fabric between them.
  2. SEALOPOL 3P protection sheetMineral-surfaced bituminous membrane, laid into the membrane while it is still warm, with dry laps of 50 to 76 mm.
  3. DURACOTE HB, two coatsPolyurethane coating where the roof stays exposed.
The re-waterproofing build-up drawn exploded: the existing slab with its old membrane stripped, then the new hot-applied membrane, SEALOPOL 3P and the DURACOTE coating

How the job runs.

  1. We strip the roofThe existing torch-on membrane is removed and taken off site. The slab is cleaned of loose material, laitance, old sealer and curing compound, and anything that needs correcting is reported before the new system goes down.
  2. Ponding areas are levelledLow spots are topped up with a mix of CHEMGROUT 215 non-shrink grout and sand.
  3. Surface conditionerCHEMCOAT SB over the roof, 300 mm up the walls and 50 mm into every pipe sleeve. It must dry fully, usually in 30 to 60 minutes, before any membrane goes on.
  4. The roof is marked into sectionsEach day's area is set out as a grid, so every section is finished the day it is started.
  5. MONOLITHIC MEMBRANE 6130K, with fabricThe first coat is spread hot with a squeegee. FLEX FLASH F fabric is broomed into it while it is warm, and the second coat goes over the fabric the same day.
  6. SEALOPOL 3PLaid into the second coat while it is still warm and tacky, on the flat and 300 mm up the walls, with dry laps of 50 to 76 mm.
  7. Then we pond testThe roof is flooded and held for 24 hours.
  8. DURACOTE HBTwo coats, where the roof stays exposed.

Walls, pipes and the melter.

Materials.

  • MONOLITHIC MEMBRANE 6130K

    Hot-applied rubberised asphalt membrane, laid as one seamless coating. It is always covered, never left exposed or trafficked.

  • CHEMCOAT SB

    Quick-drying solvent-based bitumen primer, the surface conditioner.

  • FLEX FLASH F

    Spun-bonded polyester reinforcement fabric.

  • SEALOPOL 3P

    Polymer-modified bituminous sheet membrane, surfaced with mineral slates.

  • CHEMGROUT 215

    Cementitious non-shrink grout, mixed with sand to level ponding areas.

  • DURACOTE HB

    Polyurethane coating, in two coats.

These products are made by CHEMIND. Where a project specifies another manufacturer's system, we apply that instead.

Questions we are asked.

Do you strip the old membrane?
Yes. The existing torch-on membrane is removed and taken off site, and the slab is cleaned, before the new system goes down.
Can the building stay in use while you work?
Yes. We work in sections, and each section is finished the day it is started.
What happens to low spots that pond?
They are topped up with CHEMGROUT 215 non-shrink grout and sand before the membrane goes on.
Is the new membrane left exposed?
No. It is covered with the SEALOPOL 3P protection sheet, and DURACOTE HB goes on where the roof stays exposed.
How is the finished roof tested?
It is flooded and held for 24 hours.